Test Laboratory

IMV test laboratory will operate a variety of tests: Vibration, Shock and Temperature/humidity/vibration combined environmental test. We have been in good relationships with customers with the highest of its test technique at our 3 test laboratories in Japan with high evaluation ever received by our many customers.
Not only just providing tests, we also offer technical consultant service on test conditions to be best suitable for customer's specimen, based on vibration- proof design.
We also provide right solutions for the problems, when the sample cannot pass the standard of the testing.

No idea how to decide test condition... , Design modification didn't work to solve the problem. , We want to consider a vibration/shock environment-assumed design of product from development stage. ...etc.

  • IMV (THAILAND) Co., LTD is certified to ISO / IEC17025

System Infomation

EM2401 Chamber combined vibration test system
(Horizontal / vertical excitation changeover type)

EM2401 Chamber combined vibration test system (Horizontal / vertical excitation changeover type)

A single temperature / humidity chamber is used coupled with both of vertical and horizontal vibration table.

▼EM2401

Frequency Range (Hz) 2,600
Rated
Force
Sine (kN) 24
Random (kN rms) 24
Shock (kN) 48
Maximum Accleration (m/s2) 1,142
Maximum Velocity (m/s) 2.2
Maximum Displacement
(mmp-p)
51
Maximum Load (kg) 400 (vertical),
300 (horizontal)
Slip Table (mm) W630xD630
Chamber Size WxDxH (mm) 1,000x1,000x1,000
Ambient Temperature(℃) -49 to +150
Ambient Humidity
(% RH)
20 to 98

i220 / SA1M Chamber combined vibration test system
(Vertical excitation type)

i220 / SA1M Chamber combined vibration test system (Vertical excitation type)

Industrial products are always exposed to environmental impacts, which are “climate” and“physical” environmental impacts.
Temperature and humidity chamber with vibration simulation system can simulate combined environments.

▼ i220 / SA1M

Frequency Range (Hz) 3,300
Rated
Force
Sine (kN) 8
Random (kN rms) 8
Shock (kN) 16
Maximum Accleration (m/s2) 1,159
Maximum Velocity (m/s) 2.2
Maximum Displacement
(mmp-p)
51
Maximum Load (kg) 200 (vertical)
Chamber Size WxDxH (mm) 1,000x1,000x1,000
Ambient Temperature(℃) -49 to +150
Ambient Humidity
(% RH)
20 to 98

EM2555 Chamber Combined Vibration Test System
(Large horizontal / vertical excitation changeover type)

EM2555 Chamber Combined Vibration Test System (Large horizontal / vertical excitation changeover type)

High-functionality system that accommodate high velocity and large displacement required for long duration shock tests.

▼EM2555

Frequency Range (Hz) 2,600
Rated
Force
Sine (kN) 49
Random (kN rms) 49
Shock (kN) 98
Maximum Acceleration (m/s2) 753
Maximum Velocity (m/s) 2.4
Maximum Displacement
(mmp-p)
100
Maximum Load (kg) 1,000 (vertical)
500 (horizontal)
Slip Table (mm) W1,000xD1,000
Chamber Internal Dimensions WxDxH (mm) 1,240x1,200x1,200
Temperature Range (℃) -49 to +150
Humidity Range
(% RH)
20 to 98

i240 / SA3M

i240/SA3M

Enhanced performance that expands test ranges and accommodates higher acceleration and higher frequency for automotive parts testing.

▼i240 / SA3M

Frequency Range (Hz) 2,600
Rated
Force
Sine (kN) 24
Random (kN rms) 24
Shock (kN) 48
Maximum Accleration (m/s2) 1,200
Maximum Velocity (m/s) 2.2
Maximum Displacement
(mmp-p)
51
Maximum Load (kg) 400 (vertical),
400 (horizontal)
Slip Table (mm) W800xD800

A65 / EM7HM Vibration Test System
(Vertical excitation type)

A65 / EM7HM Vibration Test System (Vertical excitation type)

A wider range of test requirements and higher test specification.
A-series meets the needs for such a versatile test environment.

▼A65 / EM7HM

Frequency Range (Hz) 2,600
Rated
Force
Sine (kN) 65
Random (kN rms) 65
Shock (kN) 130
Maximum Accleration (m/s2) 900
Maximum Velocity (m/s) 2.0
Maximum Displacement
(mmp-p)
76.2
Maximum Load (kg) 1,000 (vertical )

Test Laboratory Workflow from Inquiry to Test Operation

Test Laboratory Workflow from Inquiry to Test Operation

  • 1. Inquiry

    First, e-mail or call us. Contact us on any matters, such as how to decide a test condition etc…

    Contact Us

    Office: [TEL] +66(0)38-212-226
         [FAX] +66(0)38-212-227

    Mobile: Sales (Mizoguchi)         +66(0)97-270-6595
          Test laboratory(Sugiyama)  +66(0)86-364-7500
          Sales & service engineer(Tagoshima)
                         +66(0)80-231-2420

    E-mai: service@imv.co.th

  • 2. Quotation

    Please fill in the blank on quotaion request sheet and send e-mail or Fax to us.
    We will reply to you with test planning sheet and quotation. Clik here to download the quotation.

    TEST LAB. Quotation

  • 3. Order

    Please contact our staff to provide you with the test planning sheet. We arrange the delivery date of system and the test schedule.
    Please fill in the necessary information in the application sheet.

  • 4. Operation

    Please visit us for asking system delivery or test operation during our business hours. (Mon. to Fri. 9:00am -17:00pm).
    After the test completed, please sign the confirmation sheet.
    In case it is not possible to visit us, we send e-mail to you with the sheet, and you are kindly required to sign it and return it to us.

    Operation

  • 5. Test Report

    We provide you with the test report in a couple of days.
    In case there may be arisen some difference of testing conditions such as time, shakers to be used and etc, compared with those of original plan, we provide revised quotation.